Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/25/2010 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1) PERMIT CARD NOT ON SITE |
|
| 08/24/2010 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) WATER DISP CONN TO EXTERIOR HB AT IRRIGATION SUPPLY HAS BEEN IMPROPERLY MADE 2) ALSO IRR BACFLOW ASSEMBLY IS INSTALLED INCORRECTLY AND PRESENTS A HEATH AND SAFETY HAZARD 3) ATMOSPHERIC VACCUM BREAKERS MAY NOT HAVE VALVES INSTALLED DOWN STREAM, AND MAY NOT BE UNDER CONSTANT PRESSURE 4) AT NEW SINK; TRAP ARM MAY HAVE ONLY ONE SLIP NUT DOWN STREAM OF TRAP 5) TAIL PIECE IS LEAKING 6) 2" CLEANOUT REQUIRES 12" CLEARANCE 7) PLAN INDICATES A 2" P TRAP AND TRAP ARM |