Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING PRE-SLAB
Permit Number - T10CM01509
Inspection Description - BUILDING PRE-SLAB
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/08/2011 | BUILDING PRE-SLAB | Approved | SEE SHELL PERMIT FOR ALL REMAINING INSPECTION RESULTS | |
01/05/2011 | BUILDING PRE-SLAB | Partial Approval | ||
12/30/2010 | BUILDING PRE-SLAB | Partial Approval | SOUTH PLAZA LEVEL REQUIRES CORRECTIONS TO ELECTRICAL INSTALLATION PRIOR TO OUTSIDE POURS. | |
12/06/2010 | BUILDING PRE-SLAB | Partial Approval | LEVEL 5 NE NEED TO CHIP DOWN COLS EXTENDING INTO BEAMS...NEED TO FINISH WORK | |
12/06/2010 | BUILDING PRE-SLAB | Partial Approval | LEVEL 5 NE OK TO PLACE PM INSP | |
12/02/2010 | BUILDING PRE-SLAB | Partial Approval | 4TH LEVEL NW IN PROGRESS. NEED TO FINISH ELECTRICAL & CLEAN UP STEEL. | |
12/02/2010 | BUILDING PRE-SLAB | Partial Approval | PM INSPECTION. 4TH LEVEL NW OK TO PLACE | |
12/01/2010 | BUILDING PRE-SLAB | Partial Approval | DUCT BANK OK TO PLACE | |
11/11/2010 | BUILDING PRE-SLAB | Partial Approval | NE LEVEL 3 OK TO PLACE | |
11/10/2010 | BUILDING PRE-SLAB | Partial Approval | RAMP FROM B1 TO PLAZA LEVEL OK | |
11/05/2010 | BUILDING PRE-SLAB | Partial Approval | OK TO PLACE NW LEVEL 2. CONDUIT RUNS ALTERED TO COME UP INTO RAISED FLOOR | |
11/04/2010 | BUILDING PRE-SLAB | Partial Approval | SE B1 OK TO PLACE | |
10/29/2010 | BUILDING PRE-SLAB | Partial Approval | NE LEVEL 2 OK TO PLACE | |
10/28/2010 | BUILDING PRE-SLAB | Partial Approval | LEVEL B1 SOUTH SIDE A- E OK TO PLACE WHEN SP INSP CONFIRMS FINAL CLEAN UP | |
10/26/2010 | BUILDING PRE-SLAB | Partial Approval | SOUTH RAMP B2 - B1 OK TO PLACE | |
10/19/2010 | BUILDING PRE-SLAB | Partial Approval | NW PLAZA LEVEL OK TO PLACE TONIGHT WHEN CORRECTIONS CONFIRMED BY SPECIAL INSPECTOR. | |
10/14/2010 | BUILDING PRE-SLAB | Partial Approval | LEVEL B2 A-E/11-16 ALMOST READY. NEED QC ON REBAR CHAIRS AND CONDUIT RUNS. ALSO NEED STUDS AT LINE 14 COLUMNS. | |
10/13/2010 | BUILDING PRE-SLAB | Partial Approval | PROGRESS ONLY. NOTHING READY TO PLACE | |
10/12/2010 | BUILDING PRE-SLAB | Partial Approval | PROGRESS ONLY. NOTHING READY TO PLACE | |
10/02/2010 | BUILDING PRE-SLAB | Partial Approval | OK TO PLACE LEVEL B1 A-E/3-11 | |
10/01/2010 | BUILDING PRE-SLAB | Partial Approval | PROGRESS LEVEL B1 @ A-E/3-11 OK. MILD STEEL OK. CGS AT BEAM LOW POINTS MUST BE CORRECTED AT ALL BEAMS (1" TOO HIGH). CGS AT COLS MUST ALSO BE CORRECTED. STRESSING OF LEVEL B1 @ E-J/3-11 IS POORLY DONE. ENGINEER TO PHYSICALLY REVIEW WHAT CONTRACTOR HAS DONE AND MAKE RECOMMENDATION, PROBABLE LIFT-OFF AND RESTRESSING WILL BE REQUIRED AS WEDGES ARE NOT PROPERLY SEATED. APPEARS THAT HEADS WERE NOT PROPERLY CLEANED AND 4 TENDONS HAVE ALREADY SUFFERED SEVERE DAMAGE. |
|
09/27/2010 | BUILDING PRE-SLAB | Partial Approval | AREA 3-11/ E-J LEVEL B1 OK TO PLACE | |
09/22/2010 | BUILDING PRE-SLAB | Partial Approval | LEVEL B2 AREA A-E/3-11 OK TO PLACE | |
09/21/2010 | BUILDING PRE-SLAB | Partial Approval | LEVEL B2 AREA A-E / 3-11 STILL REQUIRES ADDED STEEL AND FINAL ELECTRIC RUNS INSTALLED. PROGRESS GENERALLY OK. | |
09/20/2010 | BUILDING PRE-SLAB | Partial Approval | STILL NEED MILD STEEL, UNIFORM AND TEMP TENDONS LEVEL B2 AREA A-E/4-11. FRIDAY POUR OF B-2 AREA E-J/3-11 COMPLETED OK. BREAKS FOR CONCRETE OVER 4KPSI SO TENSIONING IS BEING DONE TODAY. NEED RFI FOR FUTURE FIX OF 3 TEMP TENDONS BETWEEN E AND F TERMINATING AT COLD JOINT OF SLAB. |
|
09/17/2010 | BUILDING PRE-SLAB | Partial Approval | LEVEL B2 AREA 3-11/E-J CABLES AND MILD STEEL OK. SEVERAL PROBLEMS WITH THE ELECTRICAL CONDUITS IN THIS AREA. MET WITH E.O.R. TO DISCUSS NECESSARY REPAIRS. OK TO PLACE CONCRETE WHEN SPECIAL INSPECTOR CONFIRMS CORRECTIONS TO ELECTRICAL. | |
09/16/2010 | BUILDING PRE-SLAB | Partial Approval | PROGRESS LEVEL B-2 AREA E-J / 3-11 | |
09/15/2010 | BUILDING PRE-SLAB | Partial Approval | NEED TO ADDRESS GSN'S FOR C.I.P. CONCRETE KEYNOTE #11, LINE I LEVEL B2 MISSING CHAMFER. BANDED CABLES LINE I TOO CLOSE TO DECK AT MIDSPAN. SHOULD BE 1.25" TO CENTER OF CABLE. |
|
09/08/2010 | BUILDING PRE-SLAB | Partial Approval | LEVEL B3 COMPLETE |