Permit: T10CM01474

Parcel: 108193130


Addresses:

4582 N 1ST AV #170


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T10CM01474

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
07/23/2010 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
07/22/2010 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) POST CORRECT SUITE NUMBER
2) PROVIDE 1/4" PER FOOT SLOPE
3) INSTALL ABOVE SLAB TEST FITTINGS AS REQUIRED BY UPC 712 FOR TESTING SUCCESIVE SECTIONS
4) INSTALL FOAM WRAPS AT CONCRETE PENETRATIONS
5) KEEP OPEN DRAIN PIPING CAPPED TO PREVENT THE ESCAPE OF SEWER GASES OR INSTALL P TRAP AT TEMPORARY CONDENSATE CONNECTION