Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/20/2010 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
| 10/19/2010 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED PER TONY |
|
| 10/18/2010 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE CORRECT CONNECTIONS TO INTERCEPTOR AND MAKE INTERCEPTOR WATER TIGHT |
|
| 10/15/2010 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) CORRECTION FOR ITEM #60 OK 2) 4" GW FROM EXTERIOR THRU INTERCEPTOR TO EXISTING 3) WATER TEST (PARTIAL) 4) PROVIDE APPROVED TRANSITION FOR ABS TO SDR 35 (PVC PRIMED AND GLUED THIN WALL BUSHING) WITH RETEST ON INLET AND OUTLET OF INTERCEPTOR AND WATER LEVEL ABOVE INLET AND OUTLET PIPING |
|
| 10/14/2010 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) ADDITION OF FLOOR DRAINS DRAINAGE WATER TEST FOR RESTROOMS 2) PROVIDE RED LINES ON SITE FOR ALL CHANGES |
|
| 10/13/2010 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) GW PER PLAN WATER TEST TO 3' EXTERIOR EXCEPT 2" DRAINAGE FOR ITEM #60 MINUS CLEANOUT FOR INTERMEDIATE TESTING 2) SANITARY WATER TEST FOR PLAN TO EXISTING MINUS CLEANOUTS FOR INTERMEDIATE TESTING 3) FLOOR DRAINS ARE REQUIRED IN RESTROOMS WITH (2PLUS) STOOLS OR STOOL URINALS |