Date Description Inspector Results Comments
11/18/2010 PLUMBING - FINAL Approved IVRS - Inspection :*
11/16/2010 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) AAV AT DISP REQUIRED TO BE 6" ABOVE FL.
2) CLEANOUT MISSING AT HS
3) MIXING VALVES SPECIFIED
11/09/2010 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) CORRECT SLOPE AND CO PLUGS AT GT AND REMOVE DEMO
2) PROTECT PLASTIC VTRS
3) COMPLETE WORK
4) MAKE VALVES ACCESSIBLE
5) INSTALL DOME STRAINERS
6) SWEEPS AND CO'S REQUIRED ON INDIRECT WASTE 803
7) WATER SUPPLY TO DISPOSER SPECIFIED
8) WATER SUPPLIED EQUIPMENT REQUIRES UNIONS FOR SERVICING
9) SUPPORT PIPING
10) NEED CERTS AND STERILIZATION
11) INSP STOPPED
11/08/2010 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*