Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/02/2012 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 01/30/2012 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) CLOSET FLANGES ARE TO BE SCREWED OR SECURED IN AN APPROVED MANNER |
|
| 12/13/2011 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) OK TO COVER WALLS 2) NEED TO SEE CLOSET FLANGES |
|
| 12/12/2011 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) ABS HAS BEEN MODIFIED-RETEST THRU ROOF 2) REQUIRE 18" OF COPPER PRIOR TO VALVES ON A PEX SYSTEM. IE...WATER SERVICE CONNECTION, WATER HEATER VALVE AND HOSE BIBBS, ETC..... |
|
| 12/09/2011 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 12/07/2011 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) POINT OF VENT MAY NOT BE BELOW THE TRAP WEIR 2) SUPPORT HORIZONTAL PIPING OVER HEAD 3) EXTEND 1" CN TO 1ST TEE |
|
| 12/07/2011 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) PROVIDE APPROVED PLAN CHANGES TO WATER 2) A ? CUT SHEET FOR EWC AND HAND SINK |
|
| 11/30/2011 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) REVISE PLAN TO SHOW NEW 1" SERVICE 2) WATER DISTRIBUTION NOT PER PLAN, NO RED LINES ON SITE, WATER SHOW AS EXISTING HAS BEEN REPLACED 3) PLUMBERS TAPE NOT APPROVED STRAP 4) ABS WATER TEST OK 5) ? STRAPS FOR STUBOUTS 2 HOLE STRAPS FOR SUPPORT-ISOLATORS FOR HOLES |
|
| 11/23/2011 | PLUMBING - INTERMEDIATE | Not ready for Inspection | 1. PLAN DOES NOT SHOW NEW 1" CW SERVICE FROM METER TO BUILDING, REVISE PLAN, OK TO COVER SUBJECT TO REVISED PLAN. IS A RPPBP REQUIRED? 2. NO TEST ON ABS, SUPPORT VERTICAL PIPING, FHA STRAPS ON NAIL GUARDS. 3. PLAN CALLS FOR COPPER WATER PIPING, CLEAN-OUTS IN CONCRETE TO BE LOWERED AND FP CO COVER INSTALLED |
|
| 09/29/2011 | PLUMBING - INTERMEDIATE | Partial Approval |