Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/29/2011 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
| 09/27/2011 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* | |
| 09/20/2011 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) NOT INSTALLED PER PLAN 2) EACH FIXTURE REQUIRES VENTING 3) REQUIRE GREEN TRACER ON SEWER |
|
| 09/13/2011 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) WATER TEST DOWN 2) SOILS VERY WET 3) UNDERSLAB COVERED WITHOUT INSPECTION 4) BRIDGING ON SEWER LINE NOT PERMITTED 5) EXPOSE ALL PIPE AND FITTINGS 6) UNABLE TO LOCATE PLAN OR PERMIT |