Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T10CM01245

Parcel: 111050770

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
09/29/2011 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
09/27/2011 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
09/20/2011 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1) NOT INSTALLED PER PLAN
2) EACH FIXTURE REQUIRES VENTING
3) REQUIRE GREEN TRACER ON SEWER
09/13/2011 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1) WATER TEST DOWN
2) SOILS VERY WET
3) UNDERSLAB COVERED WITHOUT INSPECTION
4) BRIDGING ON SEWER LINE NOT PERMITTED
5) EXPOSE ALL PIPE AND FITTINGS
6) UNABLE TO LOCATE PLAN OR PERMIT