Permit: T10CM01151

Parcel: 126170810


Addresses:

3942 E HAYNE ST


Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Permit Number - T10CM01151

Inspection Description - EXCAVATION/LAYOUT REBAR & ZON

Inspection Status - Approved

Date Description Inspector Results Comments
09/14/2011 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
10/05/2010 EXCAVATION/LAYOUT REBAR & ZON Denied 1) NEED TO VERIFY PROPERTY PINS AT SOUTH OF BLDG
2) NEED TO POT HOLE FOOTINGS FOR INSPECTION (2) PLACES
3) NEED TO FINISH 2 X 6 RAFTERS TO SUPPORT SHEETROCK
4) NEED TO CLEAR OUT AROUND INSIDE TO VERIFY CONNECTIONS TO SOLE PLATES PER CODE
5) NEED TO MAINTAIN 6" FROM EARTH TO SIDING AND SLOPE PER CODE
6) NEED TO PROTECT ROMEX
7) NEED TO EXPOSE CONDUIT FOR NEW RUN TO SHED