Inspection History: MECHANICAL - FINAL
Permit Number - T10CM01145
Inspection Description - MECHANICAL - FINAL
Inspection Status - Not ready for Inspection
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/19/2010 | MECHANICAL - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE APPROVED FLUE PIPE 2) APPROVED CORD CLAMP 3) SECONDARY DRAIN AND SEDIMENT TRAP 4) 3 SCREWS IN PIPE 5) W/H FLUE MINIMUM 2 FT |
|
05/12/2010 | MECHANICAL - FINAL | Denied | 1) PROVIDE APPROVED FLUE PIPE AT FURNACE AND NO TAPE 2) PROVIDE APPROVED CORD CLAMPS AT UNIT 3) PROVIDE SECONDARY DRAIN AT COIL 4) PROVIDE SEDIMENT TRAP AT GAS PIPING 5) ALL FLUE PIPING SINGLE WALL JOINTS TO HAVE A MINIMUM OF 3 SCREWS 6) WATER HEATER AND FURNACE VENTS TO BE MINIMUM 2' ABOVE COOLER INLETS OR 10' AWAY |
|
05/11/2010 | MECHANICAL - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
05/10/2010 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) DOOR LOCKED, NO LOCK BOX CODE |
|
05/05/2010 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* KEY DOES NOT WORK IN DOOR |