Inspection Status: Approved
Inspection History: ROOF NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 10/05/2010 |
ROOF NAILING |
|
Approved |
|
| 09/29/2010 |
ROOF NAILING |
|
Partial Approval |
NEW ROOF AREAS OK. REPAIR ON OLD ROOF T&G OK. CRICKETS ON OLD ROOF OK TO COVER. |
| 06/30/2010 |
ROOF NAILING |
|
Partial Approval |
EXISTING ROOF OK TO COVER. |
| 06/28/2010 |
ROOF NAILING |
|
Partial Approval |
STRAPS FOR EXISTING ROOF TO WALL PINS OK. SEVERAL CS18 x 8' STRAPS STILL NEED TO BE ATTACHED BEFORE COVERING. |
| 06/17/2010 |
ROOF NAILING |
|
Partial Approval |
CEILING (EXISTING ROOF) BLOCKING AT BEAMS AND CLIPS JOIST CLIPS TO NEW BEAMS OK. |
| 06/14/2010 |
ROOF NAILING |
|
Partial Approval |
STRAPS ALONG NORTH PARAPET LINE OK. SOUTH WALL STILL NEEDS BRICK WORK BEFORE STRAPS CAN GO IN. |