Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/17/2010 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 06/16/2010 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 06/11/2010 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) 311.4 A VENT MAY NOT BE USED AS A DRAIN 2) SEE THE SHOE SIZE AND DISTANCE REQUIREMENTS OF UPC SEC 908 FOR WET VENTING |
|
| 06/08/2010 | PLUMBING - INTERMEDIATE | Not ready for Inspection | 1) TRAP ARM MAY NOT CHANGE SIZE 2) TRAP AND TRAP ARM TO BE SAME SIZE 3) TRAP MAYBE ONLY ONE SIZE LARGER THAN TAIL PIECE TO WHICH IT IS CONNECTED 4) 1 1/2" TRAP ARM LIMITED TO 3'-6" FROM TRAP WEIR TO POINT OF VENT 5) CLOSET FLANGE TO EXTEND 1/4" ABOVE FINISHED FLOOR 6) UNABLE TO SEE LISTING ON COPPER PIPE |