Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/20/2012 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 08/16/2012 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 01/25/2011 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CANNOT UNDERSTAND PANEL DIRECTORY-TO BE PER 408.4 2) GROUND TIME CLOCK 3) SECURE DEVICE TO WALL, PROPERLY TERMINATE GROUND CONDUCTOR AND NEED ARC SHIELD 4) WILL CHECK BATH FIXTURE FOR 410.43 (6) NEXT TIME ROOF: 1) INSTALL ROOF STAND FOR A/C DISCONNECT 2) TIGHTEN LOOSE FITTINGS 3) GROUNDING EQUIPMENT CONDUCTOR TO SMALL 250.122 4) BUSHING NEEDED FOR CONDUCTOR #4 AND LARGER 300.4 |