Inspection History Details
Inspection Status: Cancelled
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/12/2010 | EXT METAL CLIPS/EXT SHEATHING | Cancelled | IVRS - RI canceled | |
| 07/12/2010 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 07/09/2010 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PER SECTION A/2 NOTE 6 OSB NAILED WITH 8D NAILS FOLLOW NAILING PATTERN 2) PER DETAIL 3 LEDGER CONNECTION NOTE 2 H2.5 EACH RAFTER 3) ALL NAILING OK |