Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T10CM01035

Parcel: 114469370

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
08/23/2010 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
08/20/2010 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1) FERNCO COUPLING NOT APPROVED FOR USE IN BLDG
2) MIN. TRAP ARM DISTANCE AT WASHER (2 X DIA) 1002.2 AND MAX. FIXTURE UNITS ON A 2" VENT IS 24
3) DWV TERST OK FOR ALL EXCEPT MS
4) NEED SUPPORTS AND PROTECTION PLATES
5) INSTALL FS'S DRAINS AND WRAPS
6) WATER NOT COMPLETE OR SIZED PER PLAN
7) OK TIO COVER WALL AT FRONT HS ONLY
08/06/2010 PLUMBING - INTERMEDIATE Partial Approval NEED TO BE OK BY ENGINEER SEAL TIGHT TO PLASTIC TO BE CHANGED TOO.