Permit: T10CM01035

Parcel: 114469370

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
08/23/2010 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
08/20/2010 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
08/12/2010 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
CORRECT SLOPE
905.2 REQUIRES THAT THE VENT INVORT BO TAKEN OFF ABOVE THE CENTER LINE
905.5 POINT OF VENT MAY NOT BE BELOW WEIR.
PROVIDE DRAINAGE FHANGS AS REQUIRED. (SWOOPS)
FLOOR DRAIN AT WASHER IS NOT SHOWN ON PLAN.
AND REQUIRES A PLAN REVISION. WET VENT NO SIZED PER CODE 908-2
P-6 NOT SIZED PER PLAN ALSO PROVIDE MIN TRAP ARM DISTANCE FD NOT PER PLAN SPOT
POX ROUTING NOT AS SHOWN ON SCHOMATIC
PROVIDE A LO HOR FROM YOUR ? FOR ALL CHANGES TO PLAN. REDLINE CHANGES ON PLAN. PROVIDE CLEAN FILL AND PROTECTION OF PIPING
08/10/2010 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
08/09/2010 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*