Inspection History Details
Inspection Status: Denied
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/10/2011 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEM 2 DATED 4/14/10 STILL NOT CORRECTED, ANY FURTHER FAILED INSPECTIONS WILL RESULT IN A REFEE BEING ATTACHED TO THIS PERMIT |
|
| 11/10/2010 | MECHANICAL - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 06/28/2010 | MECHANICAL - FINAL | Cancelled | CANCELLED PER HOMEOWNER RACHEL #574-3521 | |
| 06/28/2010 | MECHANICAL - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 04/14/2010 | MECHANICAL - FINAL | Denied | 1) PROVIDE 6" CLEARANCE FROM SINGLE WALL FLUE COMBUSTIBLE MATERIALS 2) PROVIDE 1" CLEARANCE FROM DBL WALL FLUE TO COMBUSTIBLE MATERIALS 3) FLUE OUTLET TO BE A MINIMUM 24" ABOVE COOLER INLET 4) PROVIDE PERMANENT SUPPORT OF EVAPORATIVE COOLER |