Permit: T10CM00981

Parcel: 126131620


Addresses:

4625 E 15TH ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
11/19/2010 ELECTRIC - FINAL Approved IVRS - Inspection :*
11/16/2010 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 3 NEUTRALS UNDER SAME SET SCREW AT PANEL NEUTRAL BAR
2) PROTECT CONDUCTORS UNDER 8' FROM PHYSICAL DAMAGE
3) SMOKE DETECTOR TO MEET MANUFACTURERS SPECS FOR DISTANCE FROM SIDEWALLS
4) ARC FAULT BREAKERS NEEDED FOR BEDROOMS AND SMOKE DETECTORS
5) TIGHTEN SET SCREWS AND BREAK OFF HEADS FOR VACUUM BREAKERS
6) PROVIDE APPROVED GAS TIGHT FITTING FOR CLEAN OUT UNDER KITCHEN SINK