Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/07/2011 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 05/20/2011 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE COMPLETE SET OF TRUSS CALCS 2) PROVIDE AS BUILT, TRUSS CALCS NOT TO PLAN T-4 TRUSSES 3) NAILING OK |
|
| 05/12/2011 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 1/2" X 10" ALL THREAD 24" ON CENTER EPOXIED PER 5/5 DETAIL MISSING IN GARAGE 2) EPC 66 MISSING FOR BEAM TO POST CONNECTION PER PLAN 3) 2 X 6 BLOCKING MISSING PER 1/6 END WALL DETAIL AT TOP CHORD TO WALL 4) BLOCKING AT TOP AND BOTTOM CHORD TO WALL MISSING IN 6/5 DETAIL 5) 6 X 10 BEAM TO LEDGER ATTACHMENT MISSING PER SECTION B DETAIL 6) TOO MANY ITEMS TO LIST STOPPED INSPECTION 7 PLEASE RECALL WHEN READY |