Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/16/2010 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :* | |
| 04/14/2010 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* 1) FROM LAST INSPECTION REBAR TO BE ON CHAIRS, NOT DOBIS 2) PLAN CALLS FOR 2 #4'S, YOU HAVE #3 REBAR ? |
|
| 04/13/2010 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) UN-WRAPPED ABS MUST BE COVERED IN COMPACTED DIRT FOR THIS INSPECTION 2) REBAR MUST SIT UP ON CHAIRS OR WRAPPED REBAR POSTS-NOT ON BLOCK PIECES, AND SHOULD NOT BE LAYING ON ABS OR ON OLD CONCRETE-REBAR NEEDS 3" ENCASEMENT |
|
| 04/09/2010 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 03005 INSPECTION SHALL BE APPROVED PRIOR TO PRE-SLAB APPROVAL 2) AS BUILD PLUMBING IS WORN ABS PIPE SHALL HAVE 1/4" PER FOOT SLOPE AND 10' HIGH WATER TEST REQUIRED ASS ABS IN CONTACT WITH CONCRETE SHALL BE WRAPPED WITH FOAM |