Permit: T10CM00903

Parcel: 126181720

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
04/16/2010 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
04/14/2010 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
1) FROM LAST INSPECTION REBAR TO BE ON CHAIRS, NOT DOBIS
2) PLAN CALLS FOR 2 #4'S, YOU HAVE #3 REBAR ?
04/13/2010 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) UN-WRAPPED ABS MUST BE COVERED IN COMPACTED DIRT FOR THIS INSPECTION
2) REBAR MUST SIT UP ON CHAIRS OR WRAPPED REBAR POSTS-NOT ON BLOCK PIECES, AND SHOULD NOT BE LAYING ON ABS OR ON OLD CONCRETE-REBAR NEEDS 3" ENCASEMENT
04/09/2010 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 03005 INSPECTION SHALL BE APPROVED PRIOR TO PRE-SLAB APPROVAL
2) AS BUILD PLUMBING IS WORN ABS PIPE SHALL HAVE 1/4" PER FOOT SLOPE AND 10' HIGH WATER TEST REQUIRED ASS ABS IN CONTACT WITH CONCRETE SHALL BE WRAPPED WITH FOAM