Permit: T10CM00864

Parcel: 138232920


Addresses:

707 W ACADIA DR

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
04/20/2010 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
04/19/2010 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
1) COULD NOT IDENTIFY DATA PLATE
04/09/2010 PLUMBING - GAS PRESSURE TEST Partial Approval IVRS - Inspection :*
1) ITEMS 2 AND 4 DATED 4/5/10 HAVE BEEN CORRECTED, ALL OTHER ITEMS OK
2) OK TO BACK FILL TRENCH
3) PRESSURE TEST OK
4) PROVIDE LADDER TO ACCESS RTU
04/05/2010 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) WATER HEATER INSTALLATION OK
2) GAS PIPING BURRIED FROM HOUSE TO METER IS NEW AND DOES NOT MEET MINIMUL DEPTH 12" EXPOSE FULL LENGTHS OF BURIAL PIPING FOR NEXT INSPECTION
3) RTU UNIT DATA PLATE NOT IDENTIFIED
4) PROVIDE SERVICE OUTLET WITHIN 25' OF RTU
5) PROVIDE MEANS OF ELECTRICAL DISCONNECT AT WATER HEATER
6) GAS PIPING IS NEW, PROVIDE PROPER DESCRIPTION OF WORK