Permit: T10CM00675

Parcel: 13340001B

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T10CM00675

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
08/03/2010 FRAMING Approved IVRS - Inspection :*
07/30/2010 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GROUND WIRES SHARING ONE LUG MUST BE SAME SIZE
2) NEED NON POINTED SCREW IN PANEL DEAD FRONT COVER
3) SECURE RAILING WOOD POST AT N.W. CORNER OF PLATFROM AT TOP OF STAIRS
4) SECURE/SUPPORT STAIR STRINGERS WHERE NEEDED AND UPPER PLATFORM WHERE SUPPORT FROM FOOTING TO FRAME IS NOT CONTINOUS
5) DRY WALL SCREWS SHOULD NOT BE USED FOR FRAME ATTACHMENT
6) 4 FOOTINGS OK TO COVER