Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T10CM00675
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/03/2010 | FRAMING | Approved | IVRS - Inspection :* | |
07/30/2010 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) GROUND WIRES SHARING ONE LUG MUST BE SAME SIZE 2) NEED NON POINTED SCREW IN PANEL DEAD FRONT COVER 3) SECURE RAILING WOOD POST AT N.W. CORNER OF PLATFROM AT TOP OF STAIRS 4) SECURE/SUPPORT STAIR STRINGERS WHERE NEEDED AND UPPER PLATFORM WHERE SUPPORT FROM FOOTING TO FRAME IS NOT CONTINOUS 5) DRY WALL SCREWS SHOULD NOT BE USED FOR FRAME ATTACHMENT 6) 4 FOOTINGS OK TO COVER |