Permit: T10CM00674

Parcel: 11202033F


Addresses:

3950 N CAMPBELL AV


Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Permit Number - T10CM00674

Inspection Description - PLUMBING - GAS PRESSURE TEST

Inspection Status - Approved

Date Description Inspector Results Comments
04/01/2010 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
03/31/2010 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
1) SUPPORT PIPING ALONG EXTERIOR WALL (GAS PIPING)
2) INSTALL AVB'S ON HOSE BIBBS
3) PROVIDE INSPECTION HISTORY FOR PLUMBING IN THE WALLS
4) EXISTING WATER HEATER HAS BEEN REPLACED. PROVIDE DETAIL FOR CHANGES I.E. EXPANSION TANK, T & P DRAIN, I.E.C.C. REQUIREMENTS FOR INSULATION ETC...