Permit: T10CM00646

Parcel: 11201004H


Addresses:

3902 N CACTUS BL


Inspection Status: Approved

Inspection History: BUILDING - FINAL

Permit Number - T10CM00646

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
04/30/2010 BUILDING - FINAL Approved IVRS - Inspection :*
03/19/2010 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
1) A WATER HEATER SUPPORTED FROM THE GROUND SHALL REST ON LEVEL CONCRETE MIN 3" ABOVE GROUND UPC 508.3
2) PROTECTION FROM PHYSICAL DAMAGE IS REQUIRED FOR WATER HEATER INSTALLED IN CARPORT
3) CAP OR REMOVE HANDLES OF DRAIN VALVES ON COLLECTOR LOOP
4) PROPERLY INSTALL (PER MANUFACTURE INSTRUCTIONS)
5) INSULATION ON DOMESTIC PIPING-IE SEAL ALL JOINTS WITH ADHESIVE
6) PROTECT INSULATION AT STRUT CLAMPS
7) SECURE CLAMP ON EXP TANK
8) IDENTIFY WATER HEATER CIRCUIT BREAKER