Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T10CM00608
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/26/2010 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
04/21/2010 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1F) 5024-2-ELEV A LAYOUT PLAN CALLS FOR 3 B2A TRUSSES WITH MECH DOG HOUSE, HOUSE INSTALLED WITH 3 B2'S NO DOG HOUSE 2) HUS26 HANGERS REQ 16D PERIMETER TECO'S 3) MAIN GIRDERS NEED TRUSS LABELING AND TRUSS DRAWING MISSING FOR G3A GIRDER (NEED GR1, GR2 AND GR3) GIRDER DRAWINGS 4) END GABLE TRUSS TOP CHORDS NOTCHED NEED BEARING SUPPORT 5) SHIM END TRUSSES, FOR CONTINOUS BEARING 6) GARAGE SHEAR TRANSFER AND RETRO H.D. |