Permit: T10CM00606

Parcel: 141354060


Addresses:

10822 E DEEP SKY DR


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T10CM00606

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
05/11/2010 FRAMING Approved IVRS - Inspection :*
05/10/2010 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REAR GARAGE SHEAR NOT NAILED OFF
2) INADEQUATE 3-2 X 4 POST UNDER NORTH END OF G.L. WEST OF KIT/DINING OVER ROUND WALLS
3) CHECK NUMBER OF TRIMMERS FOR W. DEN WINDOW