Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/16/2012 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 11/15/2010 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) INSTALL BACK FLOW PREVENTER ON HOSE BIB 2) REPLACE FUSES FOR SMALL WEST SIDE A/C 3) INSTALL STOVE VENT CAP ON EXTERIOR 4) CORRECT PONDING BEHIND ROOF GAS PACK 5) BEEF UP GAS LINE SUPPORT BLOCKS ON ROOF 6) RAISE DISHWASHER DRAIN TO BOTTOM OF COUNTER BEFORE ENTERING DISPOSAL 7) OPEN WALL BEHIND DRESSED FROM FLOOR TO 2 FEET HIGH, FROM DOOR TO OUTLET 8) HAVE LICENSED ELECTRICIAN CHECK ALL ADDITION WIRING AND GIVE DETAILED REPORT ON COMPANY LETTER HEAD 9) HAVE LICENSED PLUMBER SCOPE DRAINS AND GIVE WRITTEN REPORT ON COMPANY LETTER HEAD |
|
| 06/04/2010 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* |