Permit: T10CM00589

Parcel: 131113380


Addresses:

5702 E 35TH ST

Inspection Status: Approved

Inspection History: BUILDING - PROGRESS

Date Description Inspector Results Comments
04/08/2010 BUILDING - PROGRESS Approved IVRS - Inspection :*
04/07/2010 BUILDING - PROGRESS Not ready for Inspection IVRS - Inspection :*
03/17/2010 BUILDING - PROGRESS Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FRONT PORCH ROOF SHEATHING TURNED THE WRONG WAY, PLYWOOD TO RUN LONG DIMENSION PERPENDICULAR TO RAFTERS
2) FOLLOW (ELECTRIC RECEPT) RUL FOR SPACING, 6'-0" FROM OPENINGS, 12'-0" FROM RECEPT TO RECEPT
3) I.D. WHERE CIRCUITS ORIGINATE
4) WEST SIDE OF REAR ADDITION YOU HAVE WOOD BELOW GRADE
5) MISSING A LANDING AT FRENCH DOORS, DRAINAGE FOR ROOF RUN OFF ABOVE DOORS
6) VERIFY, MECH DUCT CONNECTION FOR WEST ROOM
7) MISSING HEAT SOURCE REAR ADDITION
8) REMOVE WIRING IN SHED