Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T10CM00587

Parcel: 133200110


Addresses:

6534 E SPEEDWAY BL

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
04/28/2011 PLUMBING - FINAL Approved IVRS - Inspection :*
04/27/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
MAKE LISTING VISABLE BY ROTATION THE PIPE
PIPING REQ MIN 12" OF COVER, OFFSET DN AFTR MOTER
PROVIDE PROPER MAKEUP AND ALIGNMENT OF JOINTS
INSTALL TRACER WIRE. TURN WATER ON PRIOR TO INSP
REMOVE PVC FIP AND CAP CO FIP W/ A BRASS PLUG
04/21/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) CANNOT DO FINAL INSPECTION UNTIL ALL OTHER INSPECTIONS HAVE BEEN COMPLETED
2) COURTESY WALK THRU