Permit: T10CM00584

Parcel: 140220740

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Permit Number - T10CM00584

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
04/19/2010 BUILDING - FINAL Approved IVRS - Inspection :*
04/15/2010 BUILDING - FINAL Cancelled CANCELLED PER RITA OF A.R.S. RESCUE ROOTER #622-4782
04/15/2010 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
1) CONTRACTOR CANCELLED
03/18/2010 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SUPPORT TUBING ABOVE ROOF, PROVIDE APPROVED FLASHINGS AT ROOF AND PARPET
2) PROVIDE DETAIL FOR COLLECTOR INSTALLED ON FLAT ROOF
3) WATER STORAGE TANK IN GARAGE REQUIRES PHYSICAL PROTECTION FROM DAMAGE
4) ALSO APPROVED STAND REQUIRES ATTACHMENT TO STRUCTURE, PER IT'S INSTALLATION INSTRUCTIONS
5) PIPING CONNECTIONS REQUIRE DIELECTRIC PROTECTION
6) CAP ABANDON T & P DRAIN AT OLD WATER HEATER LOCATION
7) REPAIR PIPE INSULATION AT EXTERIOR