Permit: T10CM00548

Parcel: 138213780


Addresses:

7159 S CORONA PL

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
04/16/2010 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
04/12/2010 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSING CLIPS REAR PORCH
2) NOTE 1 FROM PREVIOUS
04/01/2010 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ALL BRACED WALL PANELS OSB MUST REACH TOP/TOP PLATE
2) X BRACE GABLE ENDS
3) 3 AB'S PER BRACED PANEL
4) PROVIDE CROSS SECTION REAR PORCH
5) NO ACCESS TO ROOF
6) PROVIDE TRUSS CALCS