Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/12/2010 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1) CORRECTIONS HAVE BEEN MADE 2) PLUMBING FINAL OK |
|
| 07/09/2010 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) DOOR LOCKED-NO ACCESS |
|
| 07/02/2010 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEAL WATER CLOSET AT FLOOR 2) SEAL WALL PENETRATION SUPPORT LAV MIXING VALVE 3) MIXING VALVES REQUIRED FOR SPAS 4) LAV CARRIERS SPECIFIED 5) HS LEAKING 6) DOMESTIC WATER STERILIZATION 7) EXPOSED PLASTIC ON ROOF 8) REMOVE SHARP BURRS FROM EXPOSED UNISTRUT 9) ASSEM #278144 IS LEAKING AND SUPPORT ASSEMBLY 10) PROVIDE CORRECTLY SIZED WATER FLEXES. (MAY NOT BE LINKED) 11) PROVIDE ANSI LISTING FOR WHIRLPOOL FOOT SPAS 12) GRAVITY DRAINS REQUIRE A DIRECT CONNECTION 13) DRAIN SIZE MAY NOT BE REDUCED |
|
| 06/28/2010 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* |