Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - PROGRESS
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/14/2010 | BUILDING - PROGRESS | Approved | ||
| 04/08/2010 | BUILDING - PROGRESS | Not ready for Inspection | IVRS - Inspection :* 1) COMBUSTION DUCT THRU ROOF 100 SQ INCH 2) DBL 2 X 6 NAILED TOGETHER 12" ON CENTER STAGGERED 3) ADD RAFTER AT LAUNDRY 4) USE HANGERS AT EACH END FOR DBL 2 X 6 ATTACHED TO 4 X 4 POSTS |
|
| 03/06/2010 | BUILDING - PROGRESS | Not ready for Inspection | IVRS - Inspection :* 1) TWO SHEDS ON EAST SIDE, UNDER 120 SQ FT. EXEMPT, SEE CITY AMENDMENTS=SHEDS 2) WEST SIDE SHED, ALL METAL, NON COMBUSTIBLE 3) REAR ADDITION AND LAUNDRY ROOM, NEED BLDG PERMIT-WIRING PROBLEMS AND UNDERSIZED SERVICE (60 AMP) 4) ROOF RAFTERS AND UNDERSIZED FOR SPAN 5) CLEAN UP ALL WIRING IN ARIZ ROOM AND LAUNDRY 6) NEED PLAN AND PERMIT |