Permit: T10CM00494

Parcel: 135062970


Addresses:

6926 E CALLE ORION

Inspection Status: Approved

Inspection History: BUILDING - PROGRESS

Date Description Inspector Results Comments
04/14/2010 BUILDING - PROGRESS Approved
04/08/2010 BUILDING - PROGRESS Not ready for Inspection IVRS - Inspection :*
1) COMBUSTION DUCT THRU ROOF 100 SQ INCH
2) DBL 2 X 6 NAILED TOGETHER 12" ON CENTER STAGGERED
3) ADD RAFTER AT LAUNDRY
4) USE HANGERS AT EACH END FOR DBL 2 X 6 ATTACHED TO 4 X 4 POSTS
03/06/2010 BUILDING - PROGRESS Not ready for Inspection IVRS - Inspection :*
1) TWO SHEDS ON EAST SIDE, UNDER 120 SQ FT. EXEMPT, SEE CITY AMENDMENTS=SHEDS
2) WEST SIDE SHED, ALL METAL, NON COMBUSTIBLE
3) REAR ADDITION AND LAUNDRY ROOM, NEED BLDG PERMIT-WIRING PROBLEMS AND UNDERSIZED SERVICE (60 AMP)
4) ROOF RAFTERS AND UNDERSIZED FOR SPAN
5) CLEAN UP ALL WIRING IN ARIZ ROOM AND LAUNDRY
6) NEED PLAN AND PERMIT