Permit: T10CM00451

Parcel: 138213690


Addresses:

7142 S CORONA PL

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
05/06/2010 FRAMING Approved IVRS - Inspection :*
05/03/2010 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 8' BRACED WALL PANEL OSB MUST REACH TOP/TOP PLATE, SEE BWP DETAIL PAGE 4. NEXT DENIAL 1035 WILL RESULT IN REFEE
2) PROVIDE RAISED LETTER METAL ADDRESS
3) MISSING CONDUIT AT FUTURE SOLAR WATER HEATER ELECTRICAL
04/29/2010 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NOTES 5 & 8 FROM PREVIOUS
2) MISSING CONDUIT AND 2 INSULATED PIPES FOR FUTURE SOLAR WATER HEATER PREPERATION
04/27/2010 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) HAS AS BUILT BEEN SUBMITTED TO CHANGE GARGE TJI TO TRUSSES ?
2) IF SO IS THERE A SHEAR TRANSFER AT GARAGE WALL
3) GARAGE ? OSB MUST REACH TOP/TOP PLATE SEE PAGE 4
4) ATTIC ACCESS R807.1
5) AB PLATED JOINTS 3"-12"
6) FHA STRAP AT KITCHEN EXHAUST TOP PLATE
7) CHECK SHARP POINT SCREWS AT HOMERUNS OSB
8) SHIM BEARING TRUSSES
04/23/2010 FRAMING Not ready for Inspection IVRS - Inspection :*
1) CANCELLED PER WALTER