Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/21/2010 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 04/19/2010 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED PER WALTER |
|
| 04/16/2010 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO PLANS OR CARD FOUND |
|
| 04/12/2010 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) NOTES 1 AND 5 FROM PREVIOUS |
|
| 04/01/2010 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE TRUSS CALCS/NAILING OK 2) MISSING SP4 CLIP NORTH WALL AT PANEL 3) PORCH OFF KITCHEN NOT PER PLAN, PROVIDE DETAIL SHOWING RAFTER ATTACHEMENT TO TRUSSES AS BUILT. SEE PAGE 10 4) 3 AB'S PER BRACED PANEL SEE PAGE 4 5) BRACED PANELS OSB MUST REACH TOP/TOP PLATE SEE PAGE 4 6) CLIP WINDOW HEADERS BATHROOMS 7) CLIPS MISSING NAILS THROUGHOUT 8) X-BRACE GABLE ENDS PER PLAN SEE PAGE 4 |