Permit: T10CM00440

Parcel: 14026045A

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
05/04/2010 ELECTRIC - FINAL Approved IVRS - Inspection :*
05/03/2010 ELECTRIC - FINAL Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1) BOXES MORE THAN 1/4" 314.20
2) GROUNDED CONDUCTOR 208/120 TO BE WHITE
3) PROTECT CONDUCTORS FROM SHARP METAL EDGES
ROOF:
1) SMALL UNIT A/C DISCONNECT CANNOT BE MOUNTED ON UNIT