Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T10CM00381
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/05/2010 | FRAMING | Approved | IVRS - Inspection :* | |
| 05/04/2010 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 04/30/2010 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE ENGINEER OF RECORD APPROVAL FOR SLAB SAW CUT FOR, ELECTRIC AT KITCHEN BOTTOM PLATE AT GARAGE SHEAR SPLICED, BREACHING REQUIRED 2) STRUCTUAL SHEAR, HAVE ENGINEER OF RECORD RECOMMEND REPAIRS 3) INSULATE BEHIND TUBS 4) CLEAR FLEX DUCT FROM CAN LIGHT IN KITCHEN 5) PLUMBER TAPE NOT APPROVED TO SUPPORT ABOVE PLUMBING LINES 6) PROVIDE SUPPORT UNDER TRAPS 7) CHECK ALL EXT. WALLS FOR PROPER NAILING AT STUD PLATES 8) 3" MIN. BEARING REQUIRED AT BEAMS TO POSTS |