Permit: T10CM00361

Parcel: 136241120


Addresses:

6741 E MARY DR

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
03/24/2010 BUILDING - FINAL Approved IVRS - Inspection :*
02/19/2010 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
ELECTRIC:
1) OLD SERVICE LOCATION, TURNED INTO SUB PANEL AT THIS POINT, A 2ND FEEDER WAS INSTALLED FOR SUB PANEL IN NEW ADDITION NEW SUB PANEL NEEDS TO BE FED BACK TO SERVE PANEL (DBL TAPPED AT SUB)
2) AT NEW SUB 2 POLE 40 AMP BREAKER PROTECTING A #10 CU WIRE, USE SAME BREAKER AS PANEL TYPE
3) VERIFY GROUND AND H20 BOND AT SERVICE
4) NOTE: FURNACE ROOM/MISSING COMB/RELIEF DUCTS AND T & P LINE TO EXTERIOR