Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T10CM00272
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/07/2010 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
04/27/2010 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) THIS INSPECTION FOR 03040 YARD WATER FROM RPB THRU TO BLDG INTERIOR TEST OK |
|
04/23/2010 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) RECEIVED LETTERS FOR OK OF PVC DWV FOR RAIN DRAINS, BLDG DRAINAGE, GW AND BLDG SEWER. RECEIVED OK FROM (GORMIT VANSTRATON P.E.) FOR PVC SCHEDULE 40 FOR YARD WATER PIPING |
|
04/21/2010 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) WATER TEST FOR 3" TRENCH DRAIN FROM DRAIN TO 5' NORTH |
|
04/12/2010 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) FOR UNDERGROUND RAIN DRAINAGE ONLY WATER TEST OK 2) NEED DIRECTION FROM ENGINEER FOR USE OF FOAM CORE ON BLDG INTERIOR ON THIS AND SANITARY AND GREASE WASTE SYSTEMS |