Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T10CM00236
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/15/2010 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
| 03/01/2010 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) WILL LOOK AT LETTER FOR MS DRAIN SIZE AT INTERMEDIATE INSPECTION-KEEP IT ON SITE |
|
| 02/26/2010 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) OK EXCEPT THAT PLAN SPECIFIES A 3" MS 2) PROVIDE LETTER FROM K.C. FOR CHANGE TO SPECS OR INSTALL PER PLAN |
|
| 02/25/2010 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) A BLAK TEE IS NOT LISTED TO BE INSTALLED IN A HORIZONTAL POSITION, BELOW GRADE, AS A TEST FITTIGN 2) N/H COUPLINGS ARE LISTED TO CONNECT CAST IRON. USE APPROVED COUPLINGS 3) ANY BRANCH FROM THE MAIN OVER FIRE FEET IN LENGTH REQUIRES A FULL SIZE CLEANOUT |