Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T10CM00213
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/24/2010 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
03/19/2010 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* 1) DRIP AT HS TAIL PIECE 2) BAC T REPORT |
|
03/11/2010 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* READ THE CODE SECTIONS GIVEN AND COMPLY: 1) UPC SECTION 603.1 REQUIRES THAT A NEW BACKFLOW ASSEMBLY BE TESTED AND CERTIFIED AT INSTALLATION. PROVIDE CERT 2) UPC 609.9.2 REQUIRES STERILIZATION OF WATER SYSTEM AS NOTED ON YOUR PLAN COVER PAGE 3) UPC 310 REQUIRES THAT ALL PARTS BE INSTALLED PER THIER LISTING (INSTALLATION INSTRUCTIONS) PROVIDE A MACHINE SCREW TO HOLD COVER ON CLEANOUT PLUGS, PLUG IS NOT LISTED FOR A SELF TAPPING SCREW. WATER FLEXES ARE NOT LISTED AS PIPE EXTENTIONS AND MAY NOT BE LINKED TOGETHER. EXTEND HARD PIPE AND INSTALL THE PROPER LENGTH FLEXES. ABS AND PVC MAY NOT BE GLUED TOGETHER WITHIN TH BLDG. UNCOVER THE PIPING CHANGE AT 3 COMP SINK AS PREVIOUSLY REQUESTED THE ATMOSPHERIC VAC BREAKER AT MS MAY NOT HAVE VALVES DOWN STREM. PROVIDE AN APPROVED CONNECTION FOR SOAP DISPENSER.T-6.2. LARRY NOT ON SITE. CONTRACTOR NOT ON SITE. CONTINUED DENIED INSPECTIONS WILL RESULT IN REINSPECTION FEES |
|
03/05/2010 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* NEW WORK IS IN VIOLATION OF THE FOLLOWING CODES UPC 603.1, 609.9-2 THURS OF ITEMS ARE NOTED ON YOUR PLAN. ALSO @ ICE MAKER 802-3 @ CLOSE OUT PLUGS, 316.11 AND 310.4, 310.1 @ HST 310.4 @ 3 WAY SINK. `03.5, 310-1 @ SOAP DISP. T-6-2 AND @ DIPPERWALLS 101.4.2, 103.1.1. 310.4 |