Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T10CM00213
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/03/2010 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
03/02/2010 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* | |
03/01/2010 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) POST YOUR ADDRESS 2) SYSTEM NOT UNDER TEST 3) PROVIDE PROPER VENTING 4) PROVIDE DRAINAGE FITTINGS 5) PVC THREADED FITTINGS MAY NOT BE CONCEALED 6) 3" DRAIN MAY NOT REDUCE, ALSO WILL REQUIRE FULL SIZE 7) PROVIDE MATERIAL SPEC FOR DOMESTIC WATER OR MATCH EXISTING 8) REMOVE EXCESS FLUX FROM SOLDER JOINTS 9) USE APPROVED SUPPPORTS PER THEIR LISTING 10) KEEP OPEN DRAINS CAPPED FOR SAFETY |