Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T10CM00189
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/03/2010 | FRAMING | Approved | IVRS - Inspection :* | |
03/02/2010 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1040-WINDOWS & DOORS: CHECK TOP PLATE FASTENING 6" ON CENTER ENTRY & REAR PORCH-THROUGHOUT TOP AND BOTTOM PLATES 1) COMPLY WITH DETAIL 24/SD4 SHEARWALL INTERSECTION 2) PROVIDE PROOF 1025 APPROVAL 3) CRIPPLE STUDS MISSING THROUGHOUT 4) MISSING ABS OR PINS INTERIOR SHEARWALL/DINING ROOM AND GREAT ROOM 5) COMPLY WITH DETAIL 7/SD3 MAX 1/2" CLEARANCE FLAT BLOCKING TO TOP PLATE 6) NAIL PROTECT HOSE BIBB REAR TOP PLATE 7) NAIL PLATE PLUMBING THROUGHOUT |