Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T10CM00171

Parcel: 133040470


Addresses:

9209 E HELEN ST

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
03/25/2010 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
03/11/2010 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1) THE NEW DRAWING PROVIDED REQUIRES PLAN REVIEW WITH CITY APPROVAL
2) PLUMBING CODE REQUIRES THAT RELIEF DRAIN LINES INCREASE IN SIZE WHEN COMBINED, AND RIGID TUBING. SEE PREVIOUSLY NOTED CORRECTIONS
02/18/2010 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1) FLEX MAY NOT BE USED ON RELIEF DRAIN AND LINE SIZE WOULD BE 1 1/4" TO COMBINE DRAINS
2) DRAWING INDICATORS A PRESSURE RELIEF VALVE ON BOTH SUPPLY AND RETURN LINES
3) YOUR APPROVED PLAN DOES NOT SHOW ADDITIONAL STORAGE TANK AND PROVIDE AN ACCURATE DRAWING
02/04/2010 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1) NEED ACCESS INSIDE TO INSPECT MV AND CONNECTIONS
2) PLEASE RESCHEDULE INSPECTION, I'LL TRY TO ACCOMMODATE