Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/08/2010 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* 1) BOTH DECK DRAINS LEAK |
|
| 03/04/2010 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) PIPING IS NOT INSULATED PER PLAN READ NOTE 16 ON P 2.1 |
|
| 03/02/2010 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) DWV TEST OK 2) SUPPORT LAV DRAIN 3) RELOCATE WATER TUBING SUPPORTS TOUCHING PLASTIC WASTE LINE OF UP STAIRS UNIT 4) USE ISOLATORS ON CU PASSING THRU TOP PLATE OR MAKE HOLES BIGGER 5) PROVIDE PIPE INSULAION 6) DO NOT FORGET T & P DRAIN |
|
| 02/23/2010 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* |