Permit: T10CM00113

Parcel: 123060170


Addresses:

2007 E LEE ST

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
06/24/2010 BUILDING - FINAL Approved IVRS - Inspection :*
06/23/2010 BUILDING - FINAL Partial Approval IVRS - Inspection :*
06/22/2010 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SEDIMENT TRAP REQUIRED ON GAS LINE
2) SOLID FULL SIZE LINE REQUIRED AT PTR LINES (NO FLEX LINES)
3) PAINT ROOF ABS AND PVC LINES WITH LATEX PAINT
06/02/2010 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) DDO NOT FINALED UNTIL 6/9/10
2) TIGHTEN SCREWS AT VAC BREAKERS, SHEAR OFF PTR LINE AT WATER TANKS SHALL EXTEND 6" MIN. 24" MAX.
3) VENT AT WATER HEATER AT AN ANGLE
4) HAVE MANUFACTURE APPROVE AS IS