Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T10CM00061
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/24/2010 | FRAMING | Approved | IVRS - Inspection :* 1) DRYER VENT IN 32' WITH 2-90 DEGREE BENDS 2) G.E. SPECS STATE 4" VENT WITH 2-90 DEGREE CAN GO 45' 3) MIRAMONTE WILL PROVIDE PERMANENT SIGNAGE AT DRYER LOCATION STATING DRYER REQUIREMENTS |
|
| 03/17/2010 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FIREBLOCK AT FRONT OF GARAGE 2) DRYER DUCT IN WAY OVER SPANNED AND 4" DUCT IS THE NORM. IF 5" IS USED, PERMANENT SIGNAGE IS NEEDED 3) DWV IS EMPTY-2 WET AREAS UPSTAIRS 4) STRAP TOP PLATES AT 1ST FLOOR ANGLED WALLS 5) NAIL OFF FHA STRAPS AT KIT. 3" ABS OVERBORES 6) BLOCK/HEADER OFF TOP OF LOWER MIDDLE STRINGER-PRESENTLY ON 1/2" OSB |