Permit: T10CM00041

Parcel: 12801005H

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T10CM00041

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
03/23/2010 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
1) UNDERGROUND ONLY PER RED LINE ON SITE WATER TEST OK
03/19/2010 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE A TAPPERED REDUCER ON 3 X 4 HORIZONTAL INCREASE. REDUCING N H BAND IS OK FOR VERTICAL USE ONLY
2) CORRECT SLOPE UPSTREAM OF FD, BACK PITCH PRESENT
3) DRIP AT FD
4) PROVIDE A WAY TO TEST ALL JOINTS ABV SLAB
5) INSTALL DIRECTIONAL CLEANOUT FITTING
NOTE: YOUR PLAN INDICATES A DOWN STREAM FCO