Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T10CM00041
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/23/2010 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* 1) UNDERGROUND ONLY PER RED LINE ON SITE WATER TEST OK |
|
03/19/2010 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE A TAPPERED REDUCER ON 3 X 4 HORIZONTAL INCREASE. REDUCING N H BAND IS OK FOR VERTICAL USE ONLY 2) CORRECT SLOPE UPSTREAM OF FD, BACK PITCH PRESENT 3) DRIP AT FD 4) PROVIDE A WAY TO TEST ALL JOINTS ABV SLAB 5) INSTALL DIRECTIONAL CLEANOUT FITTING NOTE: YOUR PLAN INDICATES A DOWN STREAM FCO |