Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/01/2010 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 01/29/2010 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BEHIND TABS OF T.H.A. HANGERS OVER AND NAIL OFF MSTR BEDROOM TRUSSES TO GIRDER 2) MISSING A FILLER PIECE OF ROOF SHEATHING AT RAISE MSTR BEDR ROOF TO LIVING ROOM 3) BLOCK BELOW JOINT IN FLOOR SHEATHING MSTR BED MARKED IN BLACK 4) BLOCK UNDER 2ND FLOOR FRONT POP OUT, FOR BEARING AT BOTTOM PLATE 5) THIS HOUSE HAS CLOSET OPTION AT GARAGE WALL AREA OF SHEAR IS REDUCED, SO IT INCREASED TO A #9 SHEAR WITH NOMINAL 3" MEMBERS AT JOINTS 6) MISSING ONE <7> 1ST/2ND FLOOR STRAP KIT CORNER-4 AT FRONT |