Permit: T10CM00011

Parcel: 12510003G


Addresses:

3587 E BROADWAY BL

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
07/15/2010 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
06/02/2010 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) TRASH ENCLOSURE-WALLS TOPPED OUT; OK TO GROUT AND CAP
04/14/2010 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) NORTH SIDE POP OUTS (4) TOPPED OUT AT 13'-4" GROUTED-SPECIAL INSPECTED
04/13/2010 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) POP OUTS 8' TOP OUT (8) GROUTED
04/12/2010 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) EXTERIOR POP OUTS (12) AT 0"-48" A.F.F.E. OK TO GROUT PROGRESS AREAS
04/09/2010 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) SOUTH WALL AT 24'-8"; EAST WALL 17' 4"-22'; NORTH WALL (CENTER) 17' 4" OK TO GROUT PROGRESS AREAS
04/08/2010 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) CMU MASONRY REINFORCEMENT AT 1 WEST WALL AT 1/A.3 TO BE
2) SOUTH WALL AT B/1 TO 3 FROM 16'-8" TO 20' AFFE
3) NORTH WALL AT A/1 TO 3 FROM 16'-8" TO 18' AFFE
4) SPECIAL INSPECTION BY TERRACON
04/07/2010 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
EAST WALL @ 13'4"-16'8"-17'4"; WEST WALL 13'4"-16'8"
OK TO GROUT PROGRESS AREAS
04/06/2010 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
MASONRY ABOVE MAIN ENTRY DOORS OK. FROM 10' TO LINTELS 17' ABOVE SPECIAL INSP BY TERRACON
04/05/2010 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) EAST, WEST AND SOUTH WALLS AT 8'-12' 8" OK TO GROUT PROGRESS AREAS
03/31/2010 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
03/29/2010 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) CONTINOUS CMU WALLS 4'-8' AFFE OK TO GROUT PROGRESS AREAS
03/25/2010 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) 1ST LIFT OK ON ?
03/23/2010 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*