Inspection History Details
Inspection Status: Approved
Inspection History: STORMWATER INSTALL OF CONTROLS
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/10/2012 | STORMWATER INSTALL OF CONTROLS | Approved | 1) NOI HAS BEEN POSTED AND IS IN PLACE 2) SEDIMENT DIVERSION BIRM HAS BEEN CONSTRUCTED ALONG THE PERIMETER. 3) SILT FENCE HAS BEEN TEMPORAIRILY IN AREAS WITHOUT THE BIRM 4) SEDIEMNT BASINS HAVE BEEN CONSTRUCTED. 5) GRAVEL AND FILTER FABRIC HAS BEEN PLACED IN FRONT OF STORM WATER CULVERT PIPE AT NW CORNER. 6) A STABILIZED CONSTRUCTED ENTRANCE HAS BEEN INSTALLED. 7) ENSURE MAINT IS PERFOMED AND DOCUMENTED PER YOUR PLAN. 8) ENSURE SWEEPING IS ROUTINELY ACCOMPLISHED. |
|
| 07/05/2012 | STORMWATER INSTALL OF CONTROLS | Partial Approval | CREWS HAVE INSTALLED MOST OF THE STORMWATER ITEMS ON THIS SITE. |